LXEdge 1.4.x Release Notes

Question Last Updated on: 2/25/2026

Charts created in version 1.4.0 can only be opened in version 1.4.0 and newer.
 

LXEdge Version 1.4.1

Released: February 25, 2026

Major Updates

  • Implemented centerline on top of Cardio trace.
    • For normal chart review, can be shown or hidden in sensor settings.
    • Always appears and is used for OSS-3.
  • Averaging during data collection is now applied to all sensor channels. Previously averaging was only applied to EDA.

Minor Updates

  • Added setting to toggle the chart grid on and off
  • Added settings to change the colors of the following:
    • Chart grid
    • Selected question bar at bottom of chart
    • Lines for minimum response latency and end of response onset window
  • Removed the “Hotkeys” tab in settings.
  • Advance to next question at end of question timer even if response was not marked.
  • Removed the “Select Question Set” button (used folder image) at bottom of chart. It was not functional and is no longer needed.
  • Removed the “Masseter Headset Audio” section on the “Audio/Video” tab in settings. It was not functional.
  • Minor changes to validation when submitting items to “Contact Support”.
  • Minor update to charting package.

Bug Fixes

  • Three unlabeled / non-functional Display settings were inadvertently included.
  • Issues with appearance of Windows of Evaluation when opening chart created in a different time zone.
  • Unexpected blank events would appear in NCCA / CSV export.

 


 

LXEdge Version 1.4.0

Released: January 8, 2026

Major Updates

  • Overhauled the Response Onset Window
    • Can be enabled or disabled
    • Line color can be specified
    • Minimum Response Latency (MRL) is adjustable from 0.1 to 3.0 seconds after question onset
    • End time is adjustable from 0 to 10 seconds after response
    • Can be shown in charts created in previous versions
  • Added Window of Evaluation
    • Can be enabled or disabled
    • Color can be specified; impacts the portion of WOE after the question offset
    • Duration can be adjusted between 0 and 15 seconds
    • Can be shown in charts created in previous versions
  • Most settings that impact chart appearance can now be modified while reviewing a chart
  • Related to Reports:
    • Only allow a single Report per Series
    • Add ability to delete Report from Series

Minor Updates

  • Move some settings around on the Chart settings tab
  • Add ability to specify color of non-Comparison and non-Relevant questions
  • Add indication of selected question as a bar at the bottom of the chart
  • Scoresheet print function now creates a PDF in the Attachments folder and then automatically opens this file. Previously, the print function used the Windows default printer.
  • Show more meaningful messages when chart ID check fails. Current message is “The chart failed an internal check. Please contact support.”
  • In some cases, allow chart to open even though chart ID mismatch is found. Previously, these charts would not be opened. Meaningful message will be shown to user.
  • Stop showing Pulse Arrival Time in biostatistics below the chart
  • Only show 3 decimal places for p-value near top of OSS-3 Report

Bug Fixes

  • When multiple report items were present in a Series, they would all load the same Report even if they had been created with different Report templates.
  • In OSS-3, the Kircher feature lines don’t stay with the sensor trace when centering is turned off.
  • For DLST charts, presentations unselected in the Scoresheet would still be passed into ESS processing when clicking “Show ESS Report”.
  • Question text for DLST charts was missing in OSS3-3 Report.
  • LXEdge would crash when attempting to run OSS-3 scoring when data were not present for a sensor.
  • LXEdge would crash when attempting to insert merge field into Report header or Footer.